Specification
EIA/TIA 568/A, ISO/IEC 11801, EN 50173
Transmission element – every 2 conductors stranded in pair.
EIA/TIA 568/A, ISO/IEC 11801, EN 50173
» instalation LAN net
» data transfer
Temperature ranges for laying and assembly –10 °C to +60 °C
Operation and store temperatures – 20 °C to +60 °C
Permitted minimum bending radius min. 10D
Cable lifetime min. 30 years
D – outside cable diameter
| Number of units | External diameter [mm] | Net weight
[kg/km] |
Standard production length
[m] |
| 25 | 11.5 | 134 | 1,000 |
| 50 | 16.5 | 300 | 1,000 |
| 100 | 23.5 | 600 | 1,000 |
| 200 | 31.5 | 1,150 | 1,000 |
| 300 | 39.0 | 1,700 | 1,000 |
| Conductor diameter | mm | 0.5 |
|---|---|---|
| Insulation resistance | GΩ.km | 10 |
| Max. resistance of the conductor | Ω/km | 93.8 |
| Max.mutual capacity of the pair | nF/km | 56 |
| Max. capacity unbalance | pF/100 m | 330 |
| Min. Structural Return Loss (SRL) 1–10 MHz | dB/100 m | 12 |
| Max. attenuation | dB/100 m | 2.32 × √f + 0.238 f |
| Min. near END Crosstalk (NEXT) | dB/100 m | 43–15 log (f/0.772) |