Specification
Dlk. 1.013.109y, Dlk.1.013.110y
Cable core – quads stranded in concetric layers.
Dlk. 1.013.109y, Dlk.1.013.110y
» cables are designed for general use in protective equipment
» cables are suitable for placement as in earth or conduits
Temperature ranges for laying and assembly –10 °C to +60 °C
Operation and store temperatures – 25 °C to +60 °C
Permitted minimum bending radius min. 15D
Cable lifetime min. 30 years
D – outside cable diameter
| Conductor diameter | mm | 0.9 |
|---|---|---|
| Max. loop resistance | Ω/km | 56.6 |
| Insulation resistance min. | GΩ.km | 10 |
| Mutual capacitance | nF/km | 45 |
| Effective test voltage wire/wire at 50 Hz | V | 2500 |
| Effective test voltage wire/shield at 50 Hz | V | 2500 |
| Operating voltage | Vss | 600 |
| Wire/core diameter H45 0.9/1.8 mm | |||
| Number of units | External diameter [mm] | Net weight [kg/km] | Standard production length [m] |
| 1 | 12.0 | 160 | 1,000 |
| 3 | 17.0 | 290 | 1,000 |
| 5 | 19.0 | 410 | 1,000 |
| 7 | 21.0 | 510 | 1,000 |
| 10 | 24.0 | 660 | 1,000 |
| 14 | 27.0 | 830 | 1,000 |