Specification
CW1600
Transmission element – twin pair twisted to units
CW1600
» conection cables in Local Area Networks and in private branch exchanges for telephony and signal transfers
» suitable for placement as under groung and conduit cables
» LIMITED FIRE HAZARD CABLE, fire performance BT Spec. M84
Temperature ranges for laying and assembly –10 °C to +60 °C
Operation and store temperatures – 40 °C to +70 °C
Permitted minimum bending radius min. 10D
Cable lifetime min. 30 years
D – outside cable diameter
| Conductor diameter | mm | 0.5 |
|---|---|---|
| Max. loop resistance | Ω/km | 97.8 |
| Resistence earth wire | Ω/km | 12.4 |
| Insulation resistance min | GΩ.km | 50 |
| Mutual capacitance | nF/km | 80 |
| Effective test voltage wire/wire at 50Hz | V | 500 |
| Operating voltage | V | 500 |
| Wire/core diameter 0.5/0.90 | |
| Coding | External diameter (mm) |
| CW 1600 1502H | 5.2 |
| CW 1600 1503H | 5.5 |
| CW 1600 1504H | 6 |
| CW 1600 1506H | 7.5 |
| CW 1600 1510H | 8.8 |
| CW 1600 1512H | 9.1 |
| CW 1600 1525H | 11.8 |
| CW 1600 1532H | 13.5 |
| CW 1600 1510 EH | 9.0 |
| CW 1600 1520 EH | 12.0 |
| CW 1600 1540 EH | 15.0 |
| CW 1600 1550 EH | 18.5 |
| CW 1600 1580 EH | 22.5 |
| CW 1600 1581 EH | 27.0 |
| CW 1600 1582 EH | 30.3 |
| CW 1600 1583 EH | 35.0 |
| CW 1600 1584 EH | 39.5 |